Hi~welcome to shenzhen xinmu display technology co., ltd.!
2025-08-25 140
Why is the screen display effect of the same nominal P3 three times worse?
Last year, the LED screen purchased by a exhibition center, although the parameter table read "refresh rate 1920Hz", 17% of the areas in actual tests appeared. This reveals: Parameter authenticity It is more important than paper data and needs to be verified in combination with actual scenario measurement.
Pixel spacing verification : Use a vernier caliper to measure the center distance of adjacent lamp beads, the error must be ≤0.03mm. For example, products with nominal P2.5 have a measured spacing of 2.48-2.52mm.
Brightness dynamic range:
Grayscale Trap:
Observe with a 256-level grayscale test map, the dark parts must be clearly distinguishable. Some manufacturers use 12bit driver chips to impersonate 16bit, but the actual effective grayscale is only 14bit.
Refresh rate measurement method:
When shooting with a professional camera 1/1000 shutter, the scanning line does not meet the standards. The 3840Hz product still has no afterimage when shooting rock concerts.
Color temperature consistency:
In the nine-grid area of the screen, the deviation should be <150K. The live broadcast screen in a stadium is blue due to the color temperature difference of 2000K.
Contrast Verification:
Turn off the ambient light source and use a illuminator to measure it when displaying a pure black screen. The value is ≤0.5cd/m² to meet the standard.
Protection level test:
The outdoor screen needs to pass IP65 certification - that is, soaking 1 meter of water depth for 30 minutes without water inlet, and the dust box test for 6 hours without penetration.
Temperature adaptability:
Turn on the computer immediately after freezing at -30℃ for 24 hours, and the pixel loss rate must be <0.01%. A polar scientific research station project has therefore eliminated three suppliers.
Real-time power consumption measured value:
Use a power meter to monitor the 8-hour working cycle, and the difference between peak power consumption and mean value should be <15%. Fake power consumption will lead to more than 30% of cable redundancy waste.
| Scene Type | Core parameter combination | Additional requirements |
|---|---|---|
| Commercial complex | P2.5-4/5000cd/m²/IP65 | Supports 7×24 hours of uninterrupted operation |
| Stage rental | 1920Hz refresh/15 minutes quick disassembly and assemble | Box load bearing ≤12kg/㎡ |
| Stadium | 7500cd/m² brightness/100,000 vibration tests | Horizontal viewing angle ≥160 degrees |
| Architectural curtain wall | 86% light transmittance/±45℃ temperature width | Thickness ≤28mm |
Industry Insights : A truly professional parameter table should contain three types of data - laboratory theoretical value, actual installation environment measured value, and 3-year aging prediction value. When a supplier is unable to provide a Full Life Cycle Parameter Decay Report, the promised "100,000-hour life span" may be just a marketing rhetoric. Remember when choosing: Verified parameters are good parameters。
for more product information and pricing, please contact us .