Hi~welcome to shenzhen xinmu display technology co., ltd.!
2026-01-16 191
"There was a sudden power outage at the stadium concert last week, and the backup power supply was actually hidden in the LED floor tile screen! " ——This design allowed the audience to be completely unaware of the power outage. Data shows that among LED screen black screen accidents caused by power system failures in 2024, 83% of the cases are related to improper battery installation.
As the emergency protection of the LED display screen, the battery system’s installation location directly affects the Power supply stability and Maintenance convenience . Actual measurements show that scientific layout can increase power supply interruption response speed by 90% and extend system life by 2.3 times.
Heat source avoidance : Need to be ≥15cm away from the heating element
Waterproof level : Outdoor scenes must meet IP65 standards
Maintain moving lines : Inspection channel width ≥ 40cm (measured optimal maintenance efficiency range)
| Box sandwich type | Foot cabin type | distributed micro | |
|---|---|---|---|
| Applicable scenarios | Rental screen/sports fence screen | Floor tile screen/transparent screen | Ultra-thin advertising screen |
| Capacity range | 5-20kWh | 2-8kWh | 0.5-3kWh |
| Time consuming to replace | 35-50 minutes | 15-20 minutes | 5-8 minutes |
| Thermal configuration | Dual fans + graphene thermal conductivity | Liquid metal heat sink | natural convection |
| Typical cases | Tokyo Stadium Rainstorm Emergency | Seoul transparent window project | singapore curved advertising screen |
Q: Will the battery explode if it is installed in the screen?
A: Using lithium iron phosphate battery + intelligent BMS system, the probability of loss of control is less than 0.0001%. The floor tile screen at a music festival worked continuously for 72 hours, and the temperature of the battery compartment was stable at 45℃±2℃.
Q: How to tell if the battery should be replaced?
A: Three warning signs: ①The battery life is shortened by 30%, ②The charging time is increased by 50%, and ③The surface temperature is abnormally increased by 3℃. It is recommended to do a capacity test every six months.
Q: Can the outdoor screen use batteries in rainy days?
A: The key depends on the protection level! The IP65-rated cabin can withstand the impact of heavy rain, but please note: ① Clean the pressure relief valve every month ② The wiring port must be triple sealed.
• Number of cycles : Choose a model with ≥2000 cycles (cost difference is 3 times but life span is 5 times difference)
• temperature tolerance : -20℃ to 60℃ is the basic requirement (northern projects focus on low temperature performance)
• Communication protocol : Must support MODBUS-RTU (otherwise it cannot be connected to the intelligent control system)
There is a trick for testing: ask the supplier to provide High temperature aging test report , the capacity attenuation of high-quality batteries should be <5%/year in an environment of 55°C.
Editor's opinion
Now some manufacturers simply understand "energy storage system" as installing a battery. In fact, we need to consider Electromagnetic compatibility (EMC) problem. It is recommended to choose a solution with adaptive filtering technology, which is especially important for precision equipment such as stage floor tile screens - after all, no one wants to see the screen flickering during a performance, right?
for more product information and pricing, please contact us .